Setpoint Sensor Co

Analog Sensor Setpoint - Programming Questions - …

05-06-2015 · Hi all, so I have an analog air pressure sensor hooked up to my Arduino converting the read voltage to PSI. Basically I want it to read the PSI then when I press a button I want it to use that PSI as a set point then have actions triggering two output dependant if the read value drops below or above the set PSI. Is this possible and if so can anyone point me in the right direction?

Get Price

Chat With WhatsApp

Requirements to meet CO2 monitoring | LEEDuser

26-04-2019 · Per the reference guide, it is not acceptable to arbitrarily determine CO2 setpoints. It is unlikely that a reviewer would comment on this issue unless the setpoints are highly unusual." Also we have successfully excluded 1-person and 2-person 'teleconference/phone pods' from the CO2 sensor …

Get Price

Chat With WhatsApp

Metrix Vibration

With more than 55 years of service, Metrix is the preferred supplier of industrial vibration monitoring systems and services to many of the world’s leading manufacturers and users of cooling towers, gas turbines, generators, pumps, motors, fans, reciprocating compressors, and other rotating machinery. With headquarters in Houston, Texas, we ...

Get Price

Chat With WhatsApp

CO Measurement in Coal Fired Plants | Yokogawa America

Measuring carbon monoxide (CO) can help to determine the excess oxygen setpoint. CO is the most sensitive indicator of incomplete combustion. As the amount of excess O 2 is reduced, the emergence of CO will occur before other combustibles appear (unburnt fuel). When the concentration of CO reaches the desired setpoint (typically around 400 ppm ...

Get Price

Chat With WhatsApp

CO2 Gas Detection - Calibration Technologies

CO2 Gas Detection-Refrigerant Leak Detection. When CO2 is used as refrigerant in a cascade system. Choosing Alarm set points and actions for CO2:. The typical CO2 Gas Sensor for refrigerant leak detection should be ranged 0-3% CO2, with warning set points at 0.5% (8 Hour TWA allowable exposure) and alarm set points at 1.0% (10,000ppm) CO2.. With the above warning and alarm set-points, the ...

Get Price

Chat With WhatsApp

Prodigy Control System Premium Rooftop Unit Control

factory (optional field installed CO 2 sensor required). Two modes of operation are available: setpoint and proportional. 1. Setpoint - Opens the economizer dampers to full position when CO 2 setpoint level is reached. 2. Proportional - Opens the dampers at the first set point and gradually increases it as the CO …

Get Price

Chat With WhatsApp

Environmental comfort - DesignBuilder

Environmental control. Activity tab in model data. The heating and cooling setpoint temperatures, minimum fresh air per person and illuminance requirements are related to the Activity or Usage of the zone and are accessed by opening the Environmental Comfort group header.

Get Price

Chat With WhatsApp

Controls Specifications

cooling setpoint or zone sensor cooling setpoint (30–100°F (-1–37°C)). yHeating Setpoint High Limit – Applies high limit to programmed occupied ... either auxiliary temperature sensor or CO 2 detector. yBinary input mode select for either generic or occupancy detector. In addition to the above setpoints, the

Get Price

Chat With WhatsApp

Zone sensors - Trane

CO 2 zone sensor Model description Part number Global parts Sensors Universal display (WDS) X1379082201 SEN01428 Temperature-only (WTS) X13790821 SEN01427 ºF Setpoint/override (WZS) X13790492 SEN01364 ºC Setpoint/override (WZS) X13790494 SEN01366 Receiver 100mW (milliwatt) 16 channel (North America)

Get Price

Chat With WhatsApp

Zone sensors - Trane

CO 2 zone sensor Model description Part number Global parts Sensors Universal display (WDS) X1379082201 SEN01428 Temperature-only (WTS) X13790821 SEN01427 ºF Setpoint/override (WZS) X13790492 SEN01364 ºC Setpoint/override (WZS) X13790494 SEN01366 Receiver 100mW (milliwatt) 16 channel (North America)

Get Price

Chat With WhatsApp

Requirements to meet CO2 monitoring | LEEDuser

26-04-2019 · Per the reference guide, it is not acceptable to arbitrarily determine CO2 setpoints. It is unlikely that a reviewer would comment on this issue unless the setpoints are highly unusual." Also we have successfully excluded 1-person and 2-person 'teleconference/phone pods' from the CO2 sensor …

Get Price

Chat With WhatsApp

Analog Sensor Setpoint - Programming Questions - …

05-06-2015 · Hi all, so I have an analog air pressure sensor hooked up to my Arduino converting the read voltage to PSI. Basically I want it to read the PSI then when I press a button I want it to use that PSI as a set point then have actions triggering two output dependant if the read value drops below or above the set PSI. Is this possible and if so can anyone point me in the right direction?

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us